EnviroServer ES Product Specifications


 EnviroServer® 600, 1200, 2500 GPD
The EnviroServer® is an advanced on-site wastewater treatment system for residential and light commercial applications.



Specification Charts
CONSTITUENTS1: Raw Household Sewage2 MicroSepTec Effluent
CBOD: 200 mg/1 <10 mg/l
TOTAL NITROGEN: 50 mg/l <10 mg/l
TOTAL SUSPENDED SOLIDS: 200 mg/l <10 mg/l
pH: 7.5 7.5
FECAL COLIFORM: 1,000,000,000 – 10,000,000,000 cfu/100ml <2.2 cfu/100ml
TANK DIMENSIONS: 600 GPD - 180” Length x 60” Diameter
1200 GPD - 242” Length x 72” Diameter
2500 GPD - 292” Length x 93” Diameter
POWER REQUIREMENTS: 115 VAC, 15A (gravity discharge)
115 VAC, 30A (pressure discharge)
ENERGY CONSUMPTION: 600 GPD -108 KWH per month (gravity) - $10.80@ .10/KWH).)
1200 GPD - 216 KWH per month (gravity) - $21.60@ .10/KWH).)
2500 GPD – 294 KWH per month (gravity) - $29.40@ .10/KWH).)
CAPACITY: 600 gpd in a typical regulatory requirement up to a 4-bedroom home.
1200 gpd in a typical regulatory requirement up to an 8-bedroom home
2500 gpd in a typical regulatory requirement up to a 15-bedroom home.
1. Values shown represent averages.
2. These parameters represent typical household sewage

Table 1.
Material Balance for a 600 Gallon per Day System

Stream

 

1

2

3

4

5

6

7

 

 

Influent

Settled Sludge (est.)

Primary Aerobically Treated Wastewater

Secondary Aerobically Treated Wastewater

Recirculated Water

Effluent

Air

Flow rate

gal/day

600

1.2

1800

1800

1200

600

-

Flow rate

CFM

-

-

-

-

-

-

4.3

Temperature

°F

75

75

75

75

75

75

75

Suspended Solids

mg/l

200

N/A

80

40

40

<10

-

CBOD5

mg/l

200

N/A

110

20

10

<10 

 -

TKN

mg/l

45

N/A

40

5

Text Box: }

 5

 

 -

Nitrate-N

ppm

5

N/A

10

45

45

<10

-

Dissolved Oxygen

mg/l

~0

0

5-7

5-7

4-5

4-5

N/A


Table 2.
Material Balance for a 1200 Gallon per Day System

Stream

 

1

2

3

4

5

6

7

 

 

Influent

Settled Sludge (est.)

Primary Aerobically Treated Wastewater

Secondary Aerobically Treated Wastewater

Recirculated Water

Effluent

Air

Flow rate

gal/day

1200

2.5

3600

3600

2400

1200

-

Flow rate

CFM

-

-

-

-

-

-

8.6

Temperature

°F

75

75

75

75

75

75

75

Suspended Solids

mg/l

200

N/A

80

40

40

<10

-

CBOD5

mg/l

200

N/A

110

20

10

<10 

 -

TKN

mg/l

45

N/A

40

5

Text Box: }

 5

 

 -

Nitrate-N

ppm

5

N/A

10

45

45

<10

-

Dissolved Oxygen

mg/l

~0

0

5-7

5-7

4-5

4-5

N/A


Table 3.
Material Balance for a 2500 Gallon per Day System

Stream

 

1

2

3

4

5

6

7

 

 

Influent

Settled Sludge (est.)

Primary Aerobically Treated Wastewater

Secondary Aerobically Treated Wastewater

Recirculated Water

Effluent

Air

Flow rate

gal/day

2500

5.2

7500

7500

5000

2500

-

Flow rate

CFM

-

-

-

-

-

-

13.0

Temperature

°F

75

75

75

75

75

75

75

Suspended Solids

mg/l

200

N/A

80

40

40

<10

-

CBOD5

mg/l

200

N/A

110

20

10

<10 

 -

TKN

mg/l

45

N/A

40

5

Text Box: }

 5

 

 -

Nitrate-N

ppm

5

N/A

10

45

45

<10

-

Dissolved Oxygen

mg/l

~0

0

5-7

5-7

4-5

4-5

N/A


Table 4.
Resource Usage

 

 

600 gpd System

1200 gpd System

2500 gpd System

Power Consumption:
Base System (gravity discharge)
System with Low Pressure Discharge
System with High Pressure Discharge


kWh per day


3.6
4.0
4.9


7.2
7.9
9.7


9.8
11.2
15.2


Tank Size and Retention Time
for EnviroServer® 600, 1200, and 2500

 

EnviroServer 600

EnviroServer 1200

EnviroServer 2500

Hydraulic loading,
gallons per day

600

1,200

2,500

Primary Clarifier Compartment:
   Volume, gallon:
   Retention Time, hours:

748
29.9

1566
31.3

2830
27.2

First Aerobic Compartment:
   Volume, gallon:
   Retention Time, hours:

250
10

502
10

910
8.7

Second Aerobic Compartment:
   Volume, gallon:
   Retention Time, hours:

250
10

502
10

910
8.7

Secondary Clarifier Compartment::
   Volume, gallon:
   Retention Time, hours:

250
10

486
9.7

1090
10.5

Effluent Storage/Disinfection Contact Compartment:
   Volume, gallon:
   Retention Time, hours:

210
8.4

380
7.6

1100
10.6

Total Hydraulic Volume, gallon

1,708

3,436

6,840

Total Retention Time, hours

68

69

66




For more information on how MicroSepTec can solve your septic problems
Please call TOLL FREE 877-4SEPTIC or email us at
microseptec@microseptec.com.
National Septic Foundation Logo © MicroSepTec, All Rights Reserved
(877) 4SEPTIC, Fax: (949) 916-2093
Go to Welcome Page Connect to Remote System View Online Literature Request Information